Category Of Products

Portable Spectrophotometer

Portable spectrophotometer 15A-PSP100
Illumination d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.05
Sensor Blue light enhanced sensor array
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Portable spectrophotometer 15A-PSP101
Illumination d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03
Sensor Dual light path sensor array
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Portable spectrophotometer 15A-PSP102
Illumination d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.05
Sensor Photoelectric diode sensor
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Portable spectrophotometer 15A-PSP103
Illumination d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.04
Sensor Photoelectric diode sensor
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Portable spectrophotometer 15A-PSP104
Illumination Observation angles 2°/10°
Illumination: d/8 (Diffused lighting, 8° observation angle)
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04
Sensor Dual light path sensor array
Size of integrated sphere 40 mm, alvan diffused reflection surface coating