Ion chromatograph system 30-ICG200
Ion Chromatographic Pump Type : High pressure and low pulse double plunger tandem advection pump
Maximum pressure : 35 MPa (PEEK)
Pressure display accuracy : ≤ 0.1 MPa
Flow stability : (0.2 to 0.5) ml/ min ≤ 3 %
(0.5 to 1.0) ml/ min ≤ 2 %
> 1.0 ml/ min 2 %

Flow range : 0.001 to 9.999 ml/ min
Pressure pulse : ≤ 0.5%
Conductivity detector Type : Temperature Control and Bipolar Conductivity Detector
Detection mode : Bipolar conductivity detection
Cell volume : ≤ 0.8 µL
Detection range : 0 to 35000 µS/ cm
Detection resolution : ≤ 0.0020 nS/ cm
Output voltage : - 6000 to +6000 mV (adjustable)
Baseline noise : ≤ 0.05 % F.S.
Baseline drift : ≤ 3 % FS/ 30 min
Operating temperature range : Room temperature +5 to 60°C (41 to 140°F)
Controlling temperature accuracy : ± 0.01°C
Maximum pressure : 10 MPa
Linear range : ≥ 103
Instruments linearity : ≥ 0.999
Quantitative repeatability : ≤ 1.0 %
Qualitative repeatability : ≤ 1.0 %
Minimum detectable concentration : Cl ≤ 0.0005 ug/ ml
BrO3 ≤ 0.001 ug/ ml
Li+ ≤ 0.001 ug/ ml
Flow system Plastic flow path : Made of PEEK materials
Six way Valve : PEEK material, 5000 psi pressure, independent automatic collection and flow function
Degassing Device Inner volume : 300 µl
Degassing volume : 7.5 ml
Maximum flow rate : 10 ml/ min
Degassing efficiency : Degassing 90 % at 1ml/ min
Organic tolerance : 1
Ion chromatograph system 30-ICG201
Ion Chromatographic Pump Type : High pressure and low pulse double plunger tandem advection pump
Maximum pressure : 35 MPa (PEEK)
Pressure display accuracy : ≤ 0.1 MPa
Flow stability : (0.2 to 0.5) ml/ min ≤ 3 %
(0.5 to 1.0) ml/ min ≤ 2 %
> 1.0 ml/ min 2 %
Flow range : 0.001 to 9.999 ml/ min
Pressure pulse : ≤ 0.5%
Conductivity detector Type : Temperature Control and Bipolar Conductivity Detector
Detection mode : Bipolar conductivity detection
Cell volume : ≤ 0.8 µL
Detection range : 0 to 45000 µS/ cm
Detection resolution : ≤ 0.0020 nS/ cm
Output voltage : - 6000 to +6000 mV (adjustable)
Baseline noise : ≤ 0.05 % F.S.
Baseline drift : ≤ 3 % FS/ 30 min
Operating temperature range : Room temperature +5 to 60°C (41 to 140°F)
Controlling temperature accuracy : ± 0.01°C
Maximum pressure : 10 MPa
Linear range : ≥ 103
Instruments linearity : ≥ 0.999
Quantitative repeatability : ≤ 1.0 %
Qualitative repeatability : ≤ 1.0 %
Minimum detectable concentration : Cl ≤ 0.0005 ug/ ml
BrO3 ≤ 0.001 ug/ ml
Li+ ≤ 0.001 ug/ ml
Flow system Plastic flow path : Made of PEEK materials
Six way Valve : PEEK material, 5000 psi pressure, independent automatic collection and flow function
Power supply 150 W