Category Of Products

Multi-parameter water quality Analyzer

Multi parameter water quality analyzer 25-MWA100
  • COD
  • COD determination range : 2 to 10000 mg/ L
    COD measurement accuracy : COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
    COD minimum detection limit : 0.1 mg/ L
    COD measurement time : 20 minutes
    COD repeatability : ≤ ± 5 %
    Processing sample number per batch :
    Consumables for colorimetric COD measurement : Colorimetric tubes and Cuvette
    COD reactor digestion temperature : 165 ± 0.5°C
    COD reactor digestion time : 10 min
    COD reactor time setting switches : 3 pcs
    Anti-chlorine interference : (Cl) < 1000 mg/ L No effect
  • Ammonia nitrogen
  • Ammonia nitrogen determination range : 0.02 to 60 mg/ L
    Ammonia nitrogen measurement accuracy : ≤ ± 10 %
    Ammonia nitrogen minimum detection limit : 0.01 mg/ L
    Ammonia nitrogen measurement time : 10 to 15 minutes
    Ammonia nitrogen repeatability : ≤ ± 5 %
    Processing sample number per batch :
    Consumables for colorimetric ammonia nitrogen measurement : Colorimetric tubes and Cuvette
    Ammonia nitrogen reactor time setting switches : 3 pcs
  • Total phosphorous
  • Total phosphorous determination range : 0.002 to 20 mg/ L
    Total phosphorous total phosphorous measurement accuracy : ≤ ± 5 %
    Total phosphorous minimum detection limit : 0.001 mg/ L
    Total phosphorous measurement time : 35 to 50 minutes
    Total phosphorous repeatability : ≤ ± 5 %
    Processing sample number per batch :
    Consumables for colorimetric total phosphorous measurement : Colorimetric tubes and Cuvette
    Total phosphorous reactor digestion temperature : 120 ± 0.5°C
    Total phosphorous reactor digestion time : 30 min
    Total phosphorous reactor time setting switches : 3 pcs
  • Turbidity
  • Turbidity determination range : 0.5 to 400 NTU
    Turbidity measurement accuracy : ≤ ± 5 %
    Turbidity minimum detection limit : 0.1 NTU
    Turbidity measurement time : 1 minute
    Turbidity repeatability : ≤ ± 5 %
    Consumables for colorimetric turbidity measurement : Colorimetric Cuvette
Multi parameter water quality analyzer 25-MWA101
  • COD
  • COD determination range : 5 to 5000 mg/ L
    COD measurement accuracy : COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
    COD minimum detection limit : 0.1 mg/ L
    COD measurement time : 20 minutes
    COD repeatability : ≤ ± 5 %
    Processing sample number per batch : 12 pcs
    Consumables for colorimetric COD measurement : Colorimetric tubes and Cuvette
    COD reactor digestion temperature : 165 ± 0.5°C
    COD reactor digestion time : 10 min
    COD reactor time setting switches : 3 pcs
    Anti-chlorine interference : (Cl) < 1000 mg/ L No effect
  • Ammonia nitrogen
  • Ammonia nitrogen determination range : 0.02 to 30 mg/ L
    Ammonia nitrogen measurement accuracy : ≤ ± 10 %
    Ammonia nitrogen minimum detection limit : 0.01 mg/ L
    Ammonia nitrogen measurement time : 10 to 15 minutes
    Ammonia nitrogen repeatability : ≤ ± 5 %
    Processing sample number per batch : 20 pcs
    Consumables for colorimetric ammonia nitrogen measurement : Colorimetric tubes and Cuvette
    Ammonia nitrogen reactor time setting switches : 3 pcs
  • Total phosphorous
  • Total phosphorous determination range : 0.002 to 10 mg/ L
    Total phosphorous total phosphorous measurement accuracy : ≤ ± 5 %
    Total phosphorous minimum detection limit : 0.001 mg/ L
    Total phosphorous measurement time : 35 to 50 minutes
    Total phosphorous repeatability : ≤ ± 5 %
    Processing sample number per batch : 12 pcs
    Consumables for colorimetric total phosphorous measurement : Colorimetric tubes and Cuvette
    Total phosphorous reactor digestion temperature : 120 ± 0.5°C
    Total phosphorous reactor digestion time : 30 min
    Total phosphorous reactor time setting switches : 3 pcs
  • Turbidity
  • Turbidity determination range : 0.5 to 400 NTU
    Turbidity measurement accuracy : ≤ ± 5 %
    Turbidity minimum detection limit : 0.1 NTU
    Turbidity measurement time : 1 minute
    Turbidity repeatability : ≤ ± 5 %
    Consumables for colorimetric turbidity measurement : Colorimetric Cuvette

Products added for comparison

⚠  Sorry

You can only compare maximum 3 products at once