Water Testing Instruments

Bench top turbidity meter 25-BTM100
  • Measuring range (NTU)
  • 0 to 100, 0 to 200
  • Minimum readout value (NTU)
  • 0.01, 0.1
  • Calibration point
  • 4
  • Sample volume
  • 5 to 10 ml
Bench top turbidity meter 25-BTM101
  • Measuring range (NTU)
  • 0 to 100, 100 to 400
  • Minimum readout value (NTU)
  • 0.01, 0.1
  • Calibration point
  • 5
  • Sample volume
  • 5 to 10 ml
Bench top turbidity meter 25-BTM102
  • Measuring range (NTU)
  • 0 to 100, 100 to 500
  • Minimum readout value (NTU)
  • 0.01, 0.1
  • Calibration point
  • 6
  • Sample volume
  • 5 to 10 ml
Bench top turbidity meter 25-BTM103
  • Measuring range (NTU)
  • 0 to 100, 100 to 800
  • Minimum readout value (NTU)
  • 0.01, 0.1
  • Calibration point
  • 6
  • Sample volume
  • 5 to 10 ml
Bench top turbidity meter 25-BTM104
  • Measuring range (NTU)
  • 0 to 100, 100 to 1000
  • Minimum readout value (NTU)
  • 0.01, 0.1
  • Calibration point
  • 7
  • Sample volume
  • 5 to 10 ml
Benchtop conductivity meter 25-BCM100
  • Conductivity measurement range
  • 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity accuracy
  • ± 1 % F.S.
  • Conductivity resolution
  • 0.01, 0.1, 1
  • Conductivity calibration solutions
  • 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
Benchtop conductivity meter 25-BCM101
  • Conductivity measurement range
  • 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity accuracy
  • ± 1 % F.S.
  • Conductivity resolution
  • 0.01, 0.1, 1
  • Conductivity calibration solutions
  • 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
Benchtop Dissolved oxygen meter 25-BDO100
  • Dissolved oxygen range
  • 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy
  • ± 0.5 mg / L
  • Resolution
  • 0.1 mg / L
  • Calibration points
  • 1 - 2 points
Benchtop Dissolved oxygen meter 25-BDO101
  • Dissolved oxygen range
  • 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy
  • ± 0.2 mg / L
  • Resolution
  • 0.01 mg / L
  • Calibration points
  • 1 - 2 points
Benchtop Ion meter 25-BIM100
  • Ion measurement range
  • Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
  • Calibration points
  • 2 to 5 points
Benchtop Ion meter 25-BIM101
  • Ion measurement range
  • F range: 1 × 106M – saturation, 0.02 ppm to saturation
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
  • Calibration points
  • 2 to 5 points
Benchtop Ion meter 25-BIM102
  • Ion measurement range
  • Na range: 1 × 105 - 1 M, 0.1 - 23000 ppm
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
  • Calibration points
  • 2 to 5 points
Benchtop Ion meter 25-BIM103
  • Ion measurement range
  • Ca range: 5 × 107 - 1 M, 0.02 - 4000 ppm
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
  • Calibration points
  • 2 to 5 points
Benchtop Ion meter 25-BIM104
  • Ion measurement range
  • Br range: 5 × 106 - 1 M, 0.4 - 79900 ppm
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
  • Calibration points
  • 2 to 5 points
Benchtop Ion meter 25-BIM105
  • Ion measurement range
  • NH4 range: 5 × 106 – 1 M, 0.1 – 18000 ppm
  • Ion measurement accuracy
  • ± 0.5 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
  • Calibration points
  • 2 to 5 points
Benchtop Ion meter 25-BIM106
  • Ion measurement range
  • NH3 range: 1 × 106 - 1 M, 0.02 - 17000 ppm
  • Ion measurement accuracy
  • ± 1 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
  • Calibration points
  • 2 to 5 points
Benchtop Ion meter 25-BIM107
  • Ion measurement range
  • Cn range: 5 × 106 – 0.01 M, 0.2 – 260 ppm
  • Ion measurement accuracy
  • ± 1 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
  • Calibration points
  • 2 to 5 points
Benchtop Ion meter 25-BIM108
  • Ion measurement range
  • Ag range: 1 × 107 - 1 M, 0.01 - 107900 ppm
  • Ion measurement accuracy
  • ± 1 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
  • Calibration points
  • 2 to 5 points
Benchtop Ion meter 25-BIM109
  • Ion measurement range
  • K range: 1×106 - 1M, 0.04 -39000 ppm
  • Ion measurement accuracy
  • ± 1 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
  • Calibration points
  • 2 to 5 points
Benchtop Ion meter 25-BIM110
  • Ion measurement range
  • S range: 1×107 - 1M, 0.003-32100 ppm
  • Ion measurement accuracy
  • ± 1 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
  • Calibration points
  • 2 to 5 points
Benchtop Ion meter 25-BIM111
  • Ion measurement range
  • Pb range: 1×108 – 0.1M, 0.2-20700 ppm
  • Ion measurement accuracy
  • ± 1 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
  • Calibration points
  • 2 to 5 points
Benchtop Ion meter 25-BIM112
  • Ion measurement range
  • I range: 1×108- 1M, 0.06 -127000 ppm
  • Ion measurement accuracy
  • ± 1 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
  • Calibration points
  • 2 to 5 points
Benchtop Ion meter 25-BIM113
  • Ion measurement range
  • Cu range: 1×108 - 1M, 0.06-6400 ppm
  • Ion measurement accuracy
  • ± 1 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
  • Calibration points
  • 2 to 5 points
Benchtop Ion meter 25-BIM114
  • Ion measurement range
  • Cd range: 1×106– 1M, 0.01-11200 ppm
  • Ion measurement accuracy
  • ± 1 % F.S.
  • Resolution
  • 0.001, 0.01, 0.1, 1
  • Calibration points
  • 2 to 5 points
Benchtop pH meter 25-BPM100
  • pH measurement range
  • 0.00 to 14.00 pH
  • pH accuracy
  • ± 0.05 pH
  • pH resolution
  • 0.01 pH
  • Calibration points
  • 2 points
Benchtop pH meter 25-BPM101
  • pH measurement range
  • 0.00 to 14.00 pH
  • pH accuracy
  • ± 0.01 pH
  • pH resolution
  • 0.01 pH
  • Calibration points
  • 2 points
Benchtop pH meter 25-BPM102
  • pH measurement range
  • -1.00 to 15.00 pH
  • pH accuracy
  • ± 0.01 pH
  • pH resolution
  • 0.01 pH
  • Calibration points
  • 1-3 points
Benchtop pH meter 25-BPM103
  • pH measurement range
  • -2.000 to 20.000 pH
  • pH accuracy
  • ± 0.002 pH
  • pH resolution
  • Calibration points
  • 1-5 points
Benchtop Water hardness meter 25-BWH100
  • Water hardness range
  • 0.05 mmol / L -0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
  • Accuracy
  • ± 1 % F.S.
  • Calibration points
  • 2 to 5 points
  • Calibration solution
  • 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L
Multi parameter water quality analyzer 25-MWA100
  • COD
  • COD determination range : 2 to 10000 mg/ L
    COD measurement accuracy : COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
    COD minimum detection limit : 0.1 mg/ L
    COD measurement time : 20 minutes
    COD repeatability : ≤ ± 5 %
    Processing sample number per batch :
    Consumables for colorimetric COD measurement : Colorimetric tubes and Cuvette
    COD reactor digestion temperature : 165 ± 0.5°C
    COD reactor digestion time : 10 min
    COD reactor time setting switches : 3 pcs
    Anti-chlorine interference : (Cl) < 1000 mg/ L No effect
  • Ammonia nitrogen
  • Ammonia nitrogen determination range : 0.02 to 60 mg/ L
    Ammonia nitrogen measurement accuracy : ≤ ± 10 %
    Ammonia nitrogen minimum detection limit : 0.01 mg/ L
    Ammonia nitrogen measurement time : 10 to 15 minutes
    Ammonia nitrogen repeatability : ≤ ± 5 %
    Processing sample number per batch :
    Consumables for colorimetric ammonia nitrogen measurement : Colorimetric tubes and Cuvette
    Ammonia nitrogen reactor time setting switches : 3 pcs
  • Total phosphorous
  • Total phosphorous determination range : 0.002 to 20 mg/ L
    Total phosphorous total phosphorous measurement accuracy : ≤ ± 5 %
    Total phosphorous minimum detection limit : 0.001 mg/ L
    Total phosphorous measurement time : 35 to 50 minutes
    Total phosphorous repeatability : ≤ ± 5 %
    Processing sample number per batch :
    Consumables for colorimetric total phosphorous measurement : Colorimetric tubes and Cuvette
    Total phosphorous reactor digestion temperature : 120 ± 0.5°C
    Total phosphorous reactor digestion time : 30 min
    Total phosphorous reactor time setting switches : 3 pcs
  • Turbidity
  • Turbidity determination range : 0.5 to 400 NTU
    Turbidity measurement accuracy : ≤ ± 5 %
    Turbidity minimum detection limit : 0.1 NTU
    Turbidity measurement time : 1 minute
    Turbidity repeatability : ≤ ± 5 %
    Consumables for colorimetric turbidity measurement : Colorimetric Cuvette
Multi parameter water quality analyzer 25-MWA101
  • COD
  • COD determination range : 5 to 5000 mg/ L
    COD measurement accuracy : COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
    COD minimum detection limit : 0.1 mg/ L
    COD measurement time : 20 minutes
    COD repeatability : ≤ ± 5 %
    Processing sample number per batch : 12 pcs
    Consumables for colorimetric COD measurement : Colorimetric tubes and Cuvette
    COD reactor digestion temperature : 165 ± 0.5°C
    COD reactor digestion time : 10 min
    COD reactor time setting switches : 3 pcs
    Anti-chlorine interference : (Cl) < 1000 mg/ L No effect
  • Ammonia nitrogen
  • Ammonia nitrogen determination range : 0.02 to 30 mg/ L
    Ammonia nitrogen measurement accuracy : ≤ ± 10 %
    Ammonia nitrogen minimum detection limit : 0.01 mg/ L
    Ammonia nitrogen measurement time : 10 to 15 minutes
    Ammonia nitrogen repeatability : ≤ ± 5 %
    Processing sample number per batch : 20 pcs
    Consumables for colorimetric ammonia nitrogen measurement : Colorimetric tubes and Cuvette
    Ammonia nitrogen reactor time setting switches : 3 pcs
  • Total phosphorous
  • Total phosphorous determination range : 0.002 to 10 mg/ L
    Total phosphorous total phosphorous measurement accuracy : ≤ ± 5 %
    Total phosphorous minimum detection limit : 0.001 mg/ L
    Total phosphorous measurement time : 35 to 50 minutes
    Total phosphorous repeatability : ≤ ± 5 %
    Processing sample number per batch : 12 pcs
    Consumables for colorimetric total phosphorous measurement : Colorimetric tubes and Cuvette
    Total phosphorous reactor digestion temperature : 120 ± 0.5°C
    Total phosphorous reactor digestion time : 30 min
    Total phosphorous reactor time setting switches : 3 pcs
  • Turbidity
  • Turbidity determination range : 0.5 to 400 NTU
    Turbidity measurement accuracy : ≤ ± 5 %
    Turbidity minimum detection limit : 0.1 NTU
    Turbidity measurement time : 1 minute
    Turbidity repeatability : ≤ ± 5 %
    Consumables for colorimetric turbidity measurement : Colorimetric Cuvette
Pocket Conductivity tester 25-PCT100
  • Conductivity measurement range
  • 1.0 to 199.9 µS/cm
  • Type of conductivity
  • Low range conductivity
  • Conductivity accuracy
  • ± 1 % F.S.
  • Conductivity calibration points
  • 1 point
Pocket Conductivity tester 25-PCT101
  • Conductivity measurement range
  • 10 to 1999 µS/cm
  • Type of conductivity
  • Mid-range conductivity
  • Conductivity accuracy
  • ± 1 % F.S.
  • Conductivity calibration points
  • 1 point
Pocket Conductivity tester 25-PCT102
  • Conductivity measurement range
  • 0.1 to 19.99 mS/cm
  • Type of conductivity
  • High range conductivity
  • Conductivity accuracy
  • ± 1 % F.S.
  • Conductivity calibration points
  • 1 point
Pocket Dissolved oxygen tester 25-PDO100
  • Dissolved oxygen range
  • 0.0 to 20.0 mg/L (or ppm)
  • Dissolved oxygen accuracy
  • ± 0.5 mg/L
  • % of saturation of oxygen
  • 0.0 to 200.0%
  • Sensor type
  • Polarographic dissolved oxygen probe
Pocket ORP tester 25-POT100
  • Sensor type
  • Platinum sensor
  • Connector
  • 6 pin
  • ORP measurement range
  • (-999) to 999 mV
  • ORP accuracy
  • ± 2 mV
Pocket ORP tester 25-POT101
  • Sensor type
  • Connector
  • BNC
  • ORP measurement range
  • (-999) to 999 mV
  • ORP accuracy
  • ± 2 mV
Pocket pH tester 25-PPT100
  • pH measurement range
  • 0.0 - 14.00 pH
  • Shape of electrode
  • Round glass pH electrode
  • pH measurement accuracy
  • ± 0.1 pH
  • Calibration point
  • 2 points
Pocket pH tester 25-PPT101
  • pH measurement range
  • 0.0 - 14.00 pH
  • Shape of electrode
  • Flat pH electrode
  • pH measurement accuracy
  • ± 0.1 pH
  • Calibration point
  • 2 points
Pocket pH tester 25-PPT102
  • pH measurement range
  • 0.0 - 14.00 pH
  • Shape of electrode
  • Long distance planar pH electrode
  • pH measurement accuracy
  • ± 0.1 pH
  • Calibration point
  • 2 points
Pocket pH tester 25-PPT103
  • pH measurement range
  • pH range: (-1.00) to 15.00 pH
  • Shape of electrode
  • Round glass pH electrode
  • pH measurement accuracy
  • ± 0.01 pH
  • Calibration point
  • 1 - 3 points
Pocket pH tester 25-PPT104
  • pH measurement range
  • pH range: (-1.00) to 15.00 pH
  • Shape of electrode
  • Flat pH electrode
  • pH measurement accuracy
  • ± 0.01 pH
  • Calibration point
  • 1 - 3 points
Pocket pH tester 25-PPT105
  • pH measurement range
  • pH range: (-1.00) to 15.00 pH
  • Shape of electrode
  • Long distance planar pH electrode
  • pH measurement accuracy
  • ± 0.01 pH
  • Calibration point
  • 1 - 3 points
Pocket pH tester 25-PPT106
  • pH measurement range
  • pH range: (-1.00) to 15.00 pH
  • Shape of electrode
  • Round glass pH electrode
  • pH measurement accuracy
  • ± 0.01 pH
  • Calibration point
  • 1 - 3 points
Pocket pH tester 25-PPT107
  • pH measurement range
  • pH range: (-1.00) to 15.00 pH
  • Shape of electrode
  • Flat pH electrode
  • pH measurement accuracy
  • ± 0.01 pH
  • Calibration point
  • 1 - 3 points
Pocket pH tester 25-PPT108
  • pH measurement range
  • pH range: (-1.00) to 15.00 pH
  • Shape of electrode
  • Long distance planar pH electrode
  • pH measurement accuracy
  • ± 0.01 pH
  • Calibration point
  • 1 - 3 points
Pocket Salinity tester 25-PST100
  • Salinity measurement range
  • 0.00 to 10.00 ppt
  • Salinity accuracy
  • ± 1 % F.S
  • Conductivity range
  • 0 - 20.00, 200.0, 2000 µS/cm, 20.00 mS/cm
  • Calibration solutions
  • 84 µS/cm, 1413 µS/cm, 12.88 mS/cm
Pocket Salinity tester 25-PST101
  • Salinity measurement range
  • 0.00 to 80.00 ppt
  • Salinity accuracy
  • ± 1 % F.S
  • Conductivity range
  • 0 - 200.0 µS/cm, 100 - 2000 µS/cm, 20.00 mS/cm
  • Calibration solutions
  • 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
Pocket TDS Tester 25-PTS100
  • TDS range
  • 0.5 - 100.0 ppm
  • TDS accuracy
  • ± 1 % F.S.
  • TDS factor
  • 0.4 to 1.0 (default 0.5)
  • Calibration points
  • 1 point
Pocket TDS Tester 25-PTS101
  • TDS range
  • 5 - 1000 ppm
  • TDS accuracy
  • ± 1 % F.S.
  • TDS factor
  • 0.4 to 1.0 (default 0.5)
  • Calibration points
  • 1 point
Pocket TDS Tester 25-PTS102
  • TDS range
  • 0.05 - 10.00 ppt
  • TDS accuracy
  • ± 1 % F.S.
  • TDS factor
  • 0.4 to 1.0 (default 0.5)
  • Calibration points
  • 1 point
Pocket TDS Tester 25-PTS103
  • TDS range
  • 0 - 20 ppt
  • TDS accuracy
  • ± 1 % F.S.
  • TDS factor
  • 0.1 to 1.0 (default 0.5)
  • Calibration points
  • 1 - 3 points
Portable Dissolved oxygen meter 25-PDM100
  • Dissolved oxygen range
  • 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy
  • ± 0.5 mg / L
  • Resolution
  • 0.1 mg / L
  • Calibration points
  • 1 - 2 points
Portable Dissolved oxygen meter 25-PDM101
  • Dissolved oxygen range
  • 0.0 - 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy
  • ± 0.2 mg / L
  • Resolution
  • 0.01 mg / L
  • Calibration points
  • 1 - 2 points
Portable multi-parameter water quality meter 25-PMM100
  • pH mode
  • pH measurement range : (-2.000) to 20.000 pH
    pH accuracy : ± 0.002 pH
    pH calibration points : 1 - 5 points
    pH calibration solutions : USA, NIST, DIN or user defined
  • ORP measurement
  • ORP measurement range : -1999.9 to 1999.9 mV
    ORP accuracy : ±0.2 mV
    ORP calibration points : 1 point
    ORP calibration solutions : mV & relative mV
  • Ion measurement
  • Ion measurement range : 0 to 19999 ppm, mg/L, mol/L
    Ion accuracy : ± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent)
    Ion calibration points : 2 - 5 points
    Ion calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L
  • Conductivity measurement
  • Conductivity measurement range : 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
    Conductivity accuracy : ± 0.5 % F.S.
    Conductivity calibration points : 1 - 5 points
    Conductivity calibration solutions : 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
    Temperature coefficient : 0.0 to 10.0 % / °C
    Compensation modes : Linear or pre water
    Cell constant : K = 0.1, 1, 10 or user-defined
    Normalization temperature : 20 °C or 25 °C
Portable multi-parameter water quality meter 25-PMM101
  • pH mode
  • pH measurement range : (-2.000) to 20.000 pH
    pH accuracy : ± 0.002 pH
    pH calibration points : 1 - 5 points
    pH calibration solutions : USA, NIST, DIN or user defined
  • ORP measurement
  • ORP measurement range : -1999.9 to 1999.9 mV
    ORP accuracy : ±0.2 mV
    ORP calibration points : 1 point
    ORP calibration solutions : mV & relative mV
  • Ion measurement
  • Ion measurement range :
    Ion accuracy :
    Ion calibration points :
    Ion calibration solutions :
  • Conductivity measurement
  • Conductivity measurement range : 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
    Conductivity accuracy : ± 0.5 % F.S.
    Conductivity calibration points : 1 - 5 points
    Conductivity calibration solutions : 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
    Temperature coefficient : 0.0 to 10.0 % / °C
    Compensation modes : Linear or pre water
    Cell constant : K = 0.1, 1, 10 or user-defined
    Normalization temperature : 20 °C or 25 °C
Portable multi-parameter water quality meter 25-PMM102
  • pH mode
  • pH measurement range : (-2.000) to 20.000 pH
    pH accuracy : ± 0.002 pH
    pH calibration points : 1 - 5 points
    pH calibration solutions : USA, NIST, DIN or user defined
  • ORP measurement
  • ORP measurement range : -1999.9 to 1999.9 mV
    ORP accuracy : ±0.2 mV
    ORP calibration points : 1 point
    ORP calibration solutions : mV & relative mV
  • Ion measurement
  • Ion measurement range :
    Ion accuracy :
    Ion calibration points :
    Ion calibration solutions :
  • Conductivity measurement
  • Conductivity measurement range : 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
    Conductivity accuracy : ± 0.5 % F.S.
    Conductivity calibration points : 1 - 5 points
    Conductivity calibration solutions : 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
    Temperature coefficient : 0.0 to 10.0 % / °C
    Compensation modes : Linear or pre water
    Cell constant : K = 0.1, 1, 10 or user-defined
    Normalization temperature : 20 °C or 25 °C
Portable multi-parameter water quality meter 25-PMM103
  • pH mode
  • pH measurement range : (-2.000) to 20.000 pH
    pH accuracy : ± 0.002 pH
    pH calibration points : 1 - 5 points
    pH calibration solutions : USA, NIST, DIN or user defined
  • ORP measurement
  • ORP measurement range : -1999.9 to 1999.9 mV
    ORP accuracy : ±0.2 mV
    ORP calibration points : 1 point
    ORP calibration solutions : mV & relative mV
  • Ion measurement
  • Ion measurement range :
    Ion accuracy :
    Ion calibration points :
    Ion calibration solutions :
  • Conductivity measurement
  • Conductivity measurement range :
    Conductivity accuracy :
    Conductivity calibration points :
    Conductivity calibration solutions :
    Temperature coefficient :
    Compensation modes :
    Cell constant :
    Normalization temperature :
Portable pH meter 25-PPM100
  • pH range
  • (-2.00) to 16.00 pH
  • pH accuracy
  • ± 0.01 pH
  • pH resolution
  • 0.01 pH
  • Calibration points
  • 2 points
Portable pH/ORP meter 25-PPM101
  • pH range
  • (-2.00) to 20.00 pH
  • pH accuracy
  • ± 0.002 pH
  • pH resolution
  • 0.1, 0.01, 0.001 pH
  • Calibration points
  • 1 - 5 points
Portable Turbidity meter 25-PTM100
  • Measuring range (NTU)
  • 0 to 200
  • Minimum readout value (NTU)
  • 0.1
  • Calibration point
  • Nil
  • Sample volume
  • 5 to 10 ml
Portable Turbidity meter 25-PTM101
  • Measuring range (NTU)
  • 0 to 100, 0 to 200
  • Minimum readout value (NTU)
  • 0.01, 0.1
  • Calibration point
  • 4
  • Sample volume
  • 5 to 10 ml
Portable Turbidity meter 25-PTM102
  • Measuring range (NTU)
  • 0 to 100, 100 to 400
  • Minimum readout value (NTU)
  • 0.01, 0.1
  • Calibration point
  • 5
  • Sample volume
  • 5 to 10 ml
Portable Turbidity meter 25-PTM103
  • Measuring range (NTU)
  • 0 to 100, 100 to 500
  • Minimum readout value (NTU)
  • 0.01, 0.1
  • Calibration point
  • 6
  • Sample volume
  • 5 to 10 ml
Portable Turbidity meter 25-PTM104
  • Measuring range (NTU)
  • 0 to 100, 100 to 800
  • Minimum readout value (NTU)
  • 0.01, 0.1
  • Calibration point
  • 6
  • Sample volume
  • 5 to 10 ml
Portable Turbidity meter 25-PTM105
  • Measuring range (NTU)
  • 0 to 100, 100 to 1000
  • Minimum readout value (NTU)
  • 0.01, 0.1
  • Calibration point
  • 7
  • Sample volume
  • 5 to 10 ml
Portable water hardness meter 25-PHM100
  • Water hardness range
  • 0.05 mmol / L - 0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
  • Accuracy
  • ± 1 % F.S.
  • Calibration points
  • 2 to 5 points
  • Calibration solution
  • 0.001, 0.01, 0.1 mmol / L, 0.001, 0.01, 0.1 mol / L