Category Of Products

Ion Chromatography

Ion chromatograph system 30-ICG200
  • Ion Chromatographic Pump
  • Type : High pressure and low pulse double plunger tandem advection pump
    Maximum pressure : 35 MPa (PEEK)
    Pressure display accuracy : ≤ 0.1 MPa
    Flow stability : (0.2 to 0.5) ml/ min ≤ 3 %
    (0.5 to 1.0) ml/ min ≤ 2 %
    > 1.0 ml/ min 2 %

    Flow range : 0.001 to 9.999 ml/ min
    Pressure pulse : ≤ 0.5%
  • Conductivity detector
  • Type : Temperature Control and Bipolar Conductivity Detector
    Detection mode : Bipolar conductivity detection
    Cell volume : ≤ 0.8 µL
    Detection range : 0 to 35000 µS/ cm
    Detection resolution : ≤ 0.0020 nS/ cm
    Output voltage : - 6000 to +6000 mV (adjustable)
    Baseline noise : ≤ 0.05 % F.S.
    Baseline drift : ≤ 3 % FS/ 30 min
    Operating temperature range : Room temperature +5 to 60°C (41 to 140°F)
    Controlling temperature accuracy : ± 0.01°C
    Maximum pressure : 10 MPa
    Linear range : ≥ 103
    Instruments linearity : ≥ 0.999
    Quantitative repeatability : ≤ 1.0 %
    Qualitative repeatability : ≤ 1.0 %
    Minimum detectable concentration : Cl ≤ 0.0005 ug/ ml
    BrO3 ≤ 0.001 ug/ ml
    Li+ ≤ 0.001 ug/ ml
  • Flow system
  • Plastic flow path : Made of PEEK materials
    Six way Valve : PEEK material, 5000 psi pressure, independent automatic collection and flow function
  • Degassing Device
  • Inner volume : 300 µl
    Degassing volume : 7.5 ml
    Maximum flow rate : 10 ml/ min
    Degassing efficiency : Degassing 90 % at 1ml/ min
    Organic tolerance : 1
Ion chromatograph system 30-ICG201
  • Ion Chromatographic Pump
  • Type : High pressure and low pulse double plunger tandem advection pump
    Maximum pressure : 35 MPa (PEEK)
    Pressure display accuracy : ≤ 0.1 MPa
    Flow stability : (0.2 to 0.5) ml/ min ≤ 3 %
    (0.5 to 1.0) ml/ min ≤ 2 %
    > 1.0 ml/ min 2 %
    Flow range : 0.001 to 9.999 ml/ min
    Pressure pulse : ≤ 0.5%
  • Conductivity detector
  • Type : Temperature Control and Bipolar Conductivity Detector
    Detection mode : Bipolar conductivity detection
    Cell volume : ≤ 0.8 µL
    Detection range : 0 to 45000 µS/ cm
    Detection resolution : ≤ 0.0020 nS/ cm
    Output voltage : - 6000 to +6000 mV (adjustable)
    Baseline noise : ≤ 0.05 % F.S.
    Baseline drift : ≤ 3 % FS/ 30 min
    Operating temperature range : Room temperature +5 to 60°C (41 to 140°F)
    Controlling temperature accuracy : ± 0.01°C
    Maximum pressure : 10 MPa
    Linear range : ≥ 103
    Instruments linearity : ≥ 0.999
    Quantitative repeatability : ≤ 1.0 %
    Qualitative repeatability : ≤ 1.0 %
    Minimum detectable concentration : Cl ≤ 0.0005 ug/ ml
    BrO3 ≤ 0.001 ug/ ml
    Li+ ≤ 0.001 ug/ ml
  • Flow system
  • Plastic flow path : Made of PEEK materials
    Six way Valve : PEEK material, 5000 psi pressure, independent automatic collection and flow function
  • Power supply
  • 150 W