Gas Chromatography 30-GCG101

GAS CHROMATOGRAPHY
30-GCG101

Gas Chromatography 30-GCG101
GAS CHROMATOGRAPHY 30-GCG101

Gas chromatography system is equipped with superior quality, high-precision electronic flow/ pressure control system. This gas chromatograph system has accurate tracking design and accurate programmed heating control system for the furnace temperature. Incorporated with safe and reliable functions of self-ignition and hydrogen leakage self-protection.

FEATURES

  • EPC controlled injector flow, column carrier flow and detector gas flow 7 steps temperature rising function
  • LCD display to view test parameters
  • Different detectors with high stability and sensitivity for selection
  • Quick heating and cooling system
  • Gas circuit technology with blowback function
  • Adopted with imported valve configuration system
  • Use of 8 digit auto injector
  • Six individual controlling heating areas

SPECIFICATIONS

Chromatography column type Capillary or Packed column
Chromatography column length 100 to 300 mm
Chromatography column diameter 0.2 to 0.5 mm
Temperature operating range Higher than the room temperature of 5 °C to 450°C
Liquid nitrogen cold trap: -80 °C to 400 °C
Dry ice cold trap: -55 °C to 400 °C
Maximum programmed heating speed 120 °C/min
Programmed temperature steps 7 steps
Temperature setting precision 0.1 °C
Programmed heating rate 0.1 to 120 º C/min (increment of 0.1°C)
The longest method run time 999.99 min
Furnace dimension 280 × 300 ×180 mm
Heating area Six individual controlling heating areas
Maximum temperature in auxiliary heating area: 300 °C
Detectors Following detectors can be selected as per the requirement
FID Maximum using temperature: 450 °C
Minimum LOD: ≤ 2.5 pg C / s [n - C16]
Linear dynamic range: 107 (± 10 %)
Data collection frequency: Maximum 100 Hz
TCD Maximum using temperature: 400 °C
Minimum LOD: < 400 pg C3 H8 / ml(He)
Linear dynamic range: 105 (± 5 %)
Data collection frequency: Maximum 100 Hz
The design of monofilament TCD and Micro-ECD
FPD Maximum using temperature: 250 °C
Minimum LOD: < 4 pg S / sec, < 1 pg P/sec
Linear dynamic range: > 103 (S), > 104 (P)
Optional: 105 g S / g C, 106 g P / g C
ECD Maximum using temperature: 400 °C
Type of gas compensation detector: 5 % methane, argon, nitrogen
Minimum LOD: > 107 S, > 107 P
Linear dynamic range: 5 × 105
Data collection frequency: Maximum 100 Hz
Radioactive source: < 12 mCi 63 Ni
NPD Maximum using temperature: 450 °C
Minimum LOD: < 0.2 pg N / sec, < 0.2 pg P / sec
Minimum LOQ: < 3 pg / sec
Linear dynamic range: 105 N, 105 P
APPLICATIONS

Used in quality supervision of medicines, foods and chemicals, oil extraction and refining industry, petrochemical industry, electronic high-purity gas industry and scientific research institutes.