Category Of Products

Spectrophotometer

Atomic Absorption Spectrophotometer 15A-AAS100
  • Monochromator
  • Czerny-Turner
  • Wavelength range
  • 190 – 900 nm
  • Spectral Bandwidth
  • 0.2,0.4,1.0,2.0 nm, multi-speed automatic switching
  • Wavelength accuracy
  • ± 0.25 nm
Atomic Absorption Spectrophotometer 15A-AAS101
  • Monochromator
  • Wavelength range
  • 190 - 900 nm
  • Spectral Bandwidth
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
  • Wavelength accuracy
  • ≤ ± 0.5 nm
Atomic Absorption Spectrophotometer 15A-AAS103
  • Monochromator
  • Wavelength range
  • 180 - 900 nm
  • Spectral Bandwidth
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer 15A-AAS104
  • Monochromator
  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer 15A-AAS105
  • Monochromator
  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
  • Wavelength accuracy
  • ≤ 0.15 nm
Double Beam UV/Vis Spectrophotometer 15A-DUS105
  • Wavelength range
  • 190 ~ 1100 nm
  • Spectral bandwidth
  • 2 nm
  • Wavelength accuracy
  • 0.5 nm
  • Wavelength repeatability
  • ≤ 0.2 nm
Nano Spectrophotometer 15A-NSP100
  • Cuvette
  • Temperature
  • PC
  • Wavelength range
  • 200 - 800 nm
Nano Spectrophotometer 15A-NSP101
  • Cuvette
  • Temperature
  • PC
  • Wavelength range
  • 200 - 850 nm
Nano Spectrophotometer 15A-NSP102
  • Cuvette
  • Temperature
  • PC
  • Wavelength range
  • 200 - 850 nm
Nano Spectrophotometer 15A-NSP200
  • Cuvette
  • Temperature
  • PC
  • Wavelength range
  • 230 nm, 260 nm, 280 nm
Nano Spectrophotometer 15A-NSP201
  • Cuvette
  • Temperature
  • PC
  • Wavelength range
  • 230 nm, 260 nm, 280 nm
Nano Spectrophotometer 15A-NSP300
  • Cuvette
  • No
  • Temperature
  • PC
  • Inbuilt
  • Wavelength range
  • 190 - 850 nm
Nano Spectrophotometer 15A-NSP301
  • Cuvette
  • Yes
  • Temperature
  • PC
  • Inbuilt
  • Wavelength range
  • 190 - 850 nm
Nano Spectrophotometer 15A-NSP302
  • Cuvette
  • Yes
  • Temperature
  • Room Temperature 42 ºC
  • PC
  • Inbuilt
  • Wavelength range
  • 190 - 850 nm
Nano Spectrophotometer 15A-NSP303
  • Cuvette
  • Yes
  • Temperature
  • 4 ºC - 42 ºC (Heating & Cooling)
  • PC
  • Inbuilt
  • Wavelength range
  • 190 - 850 nm
NIR Spectrophotometer 15A-NIR100
  • Wavelength range
  • 900 ~ 1700 nm
  • Wavelength accuracy
  • ± 1 nm
  • Wavelength reproducibility
  • ≤ 1 nm
  • Scanning interval
  • 1 nm , 4 nm , 8 nm , 16 nm
Portable spectrophotometer 15A-PSP100
  • Illumination
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
  • Sensor
  • Blue light enhanced sensor array
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
Portable spectrophotometer 15A-PSP101
  • Illumination
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03
  • Sensor
  • Dual light path sensor array
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
Portable spectrophotometer 15A-PSP102
  • Illumination
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.05
  • Sensor
  • Photoelectric diode sensor
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
Portable spectrophotometer 15A-PSP103
  • Illumination
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
    Maximum:0.04
  • Sensor
  • Photoelectric diode sensor
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
Portable spectrophotometer 15A-PSP104
  • Illumination
  • Observation angles 2°/10°
    Illumination: d/8 (Diffused lighting, 8° observation angle)
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08%
    Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04
  • Sensor
  • Dual light path sensor array
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
Table top spectrophotometer 15A-TTS100
  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
  • Sensor
  • Dual light path sensor array
Table top spectrophotometer 15A-TTS101
  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
  • Sensor
  • Dual light path sensor array
Table top spectrophotometer 15A-TTS102
  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology )
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 15.2 cm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
  • Sensor
  • Dual light path sensor array
Table top spectrophotometer 15A-TTS103
  • Illumination system
  • d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
  • Sensor
  • Dual light path sensor array